ELECTRICAL DATA |
Output - AC on Grid |
Rated AC Power: 3800W |
AC Power Output: 3800W |
AC Output Voltage: 211-264Vac |
Frequency Range: Min: 59.3Hz; Nom: 60Hz; and Max: 60.5Hz |
Maximum Continuous Output Current: 16 Amps |
Utility Monitoring, Islanding Protection, County Configurable Thresholds: Yes |
Charge Battery from AC (if Allowed): Yes |
Typical Nighttime Power Consumption: < 2.5W |
Output - AC Backup |
Rated AC Power in Backup Operation: 3050W |
Peak AC Power (< 10 sec) in Backup Operation: 3400W |
AC (L-N) Output Voltage Range in Backup: 105-132Vac |
AC Frequency Range in Backup: Min: 55Hz; Nom: 60Hz; and Max: 65Hz |
Maximum Continuous Output Current in Backup: 12.7 Amps |
Peak AC Current (< 10 sec) in Backup Operation: 14.2 Amps |
Output - Smart EV Charger AC |
Rated AC Power: 9600W |
AC Output Voltage Range: 211-264Vac |
AC Frequency Range: Min: 59.3Hz; Nom: 60Hz, and Max: 60.5Hz |
Max. Continuous Output Current @240V (Grid, PV and Battery): 40Aac |
Input - DC (PV and Battery) |
Transformer-less, Ungrounded: Yes |
Max. Input Voltage: 480Vdc |
Nom DC Input Voltage: 350Vdc |
Reverse-Polarity Protection: Yes |
Ground-Fault Isolation Detection: 600kΩ Sensitivity |
Input - DC (PV) |
Max. DC Power: 7600W |
Max. Input Current: 10.5Adc |
Max. Input Short Circuit Current: 45Adc |
Max. Inverter Efficiency: 99.2% |
2-Pole Disconnection: Yes |
Input - DC (Battery) |
Supported Battery Types: LG Chem RESU10H |
Number of Batteries per Inverter: 1 or 2 |
Max. Battery Capacity per Inverter: 19.6kWh |
Continuous Power per Inverter: 5000W |
Peak Power: 6900Adc |
Max. Input Current @240V: 18Adc |